Dolby Laboratories DM100 Bedienungsanleitung Seite 29

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 28
Dolby Model DP583 Frame Synchronizer User’s Manual Front-Panel Menus
4-3
4.2.3 Error Stats
Press Enter to reset the counter(s) while the screen is displayed.
Dolby E Errors
CRC: 01
Counts Dolby E CRC Errors
Dolby D Errors
CRC: 01
Counts Dolby Digital CRC errors.
Main AES3 Errors
P:00 CD:00 CF:00
Counts parity errors
in the main AES
input.
|
|
|
|
|
|
|
Counts the number of
times the main AES input
signal has degraded to the
point where reception is
unreliable.
Counts carrier coding errors in the main AES input.
Main AES3 Errors
CCRC:06
Counts channel status CRC errors in the main AES input.
Similar error counter menus exist for the AES reference input.
4.2.4 Other Status Menus
Other status menus display the following information:
The frame rate of the incoming Dolby E signal
Current status of the tracking input, if selected
Condition of the digital input, video reference input, and AES reference input
Firmware version
MAIN
Seitenansicht 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare