DP571 Dolby
®
E Encoder User’s Manual
ix
Fuse Information
WARNING: To reduce the risk of fire, replace fuses only with the same type
and rating.
Each unit uses a universal switching power supply that handles the full range of
nominal mains voltages between 90 and 264 VAC and any frequency between 50 and
60 Hz.
Check Main Fuse
The main fuse rating is T 1A L (1 amp, 250 V, 20 mm, time-lag, low breaking
capacity) for all operating voltages.
WARNING: The power to the unit must be off when the following steps are
performed. Ensure that the main power cable to the unit is not connected to a
power source.
To inspect or replace the main fuse:
1. Open the fuse compartment door in the AC power input housing with a small flat-
blade screwdriver. (See the following figure.)
2. Check that the fuse in the active (lower) fuse carrier is the correct rating. The fuse
carrier must be inserted into the compartment with the orientation shown in the
following figure. Do not force the carrier into the compartment or both could be
damaged.
3. Snap the fuse compartment door closed.
Open the doorOpen the door
Active fuseActive fuse
Fuse carrier
Metal clip installed on
unused side of carrier
Metal clip installed on
unused
side of carrier